ITALIANO
CDB ENGINEERING SPA

Your Partner in filtration and process equipment

Filters and Strainers ┬╗ Filters ┬╗ Cast steel Basket Filters "FBC"

Other Filters:

Duplex Basket Filters Duplex Basket Filters Duplex Basket Filters Self cleanning Filters Cartridge Filters High pressure drop Basket Filters

Designed to ASME B16.34 the strainers bodies are producedwith a superior wall thickness for corrosion allowance.

Standard strainers are equipped with screens for the averange service of most mediums (steam, gas, air, oil, chemicals, ect.).

The large screen open area ensures an efficient filtering action with low pressure drop.

Filtering area to inlet area ratio is larger than 3 to 1.

Screen area manufactured with perforated plate in the materials and with the perforation specified in the relevant tables.

Different filtrations or materials area available on request.

Special Basket Filters Activated Carbon Filters In-line Basket Filters Offset Basket Filters Angle Basket Filters Forged Basket Filters
POS.DESCR.STD MAT.STD MAT.STD MAT.SPARE
1BODYASTM A216WCBASTM A351 CFB(M)ASTM A352LCB 
2SCREENSs 304Ss 304-316Ss304X
3GASKETSW 316/GRAPHITESW 316/GRAPHITESW 16/GRAPHITEX
4COVERASTM A105NASTM A182 F304/316ASTM A350LCB 
5BOLTSASTM A193B7ASTM A193BBL7 
6NUTSASTM A1942HASTM A194GRBGR4 
7DRAINASTM A105NASTM A182 F316ASTM A105N 

CDB ENGINEERING SPA
 

Tel. +39 0377 912268/5

Fax +39 0377 910668

Email info@cdbengineering.com

CONNECTIONS
FLANGEDASME B16.5
 
Cast steel Basket Filters
SIZE (INCHES)ANSI 150#ANSI 300#
LHH1KGLHH1KG
2"2902071103630920511038
3"3502651404735026514049
4"4203501606042035016065
6"550500180170550500180178
8"700650240290725650240299
10"850850315400850850315415
12"950950350535    
14"11501245395920    
16"1100800430950    
03/10

All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainers installed with the flow following the same directions as the flow direction arrow cast onto the strainers body.

For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

Strainers should never be installed in vertical pipelines in the upward flow condition.

COMPANY

PRODUCTS

INFO

Linkedin Youtube chanel

All right reserved. Copyright 2017 by CDB ENGINEERING SPA

Address: L. Maggi, 19 - 26841 Casalpusterlengo (LO) Italy

Paid up share Capital Euro 1.050.000,00 i.v.

VAT NO. 02977730965 - N. REA 1449742

Trademarks are register by their owner