The Float Trap is probably the oldest on the market and even today it finds a fairly widespread use.

With regard to construction, there are several minor variations, but the operating principle is always the same.

The principal advantage of the float trap is, that it discharges all condensate as soon as it presents itself, independent of its temperature. The main inherent disadvantage is that it will not discharge air. As a result this trap has to be provided with an air vent, to be opened periodically, particularly during start-up.

However, very often these valves are either forgotten to be opened, or to be closed, thus resulting in flooded heat exchangers, or in a considerable loss of live steam.

Frequently a float traps is therefore provided with an automatic air vent e which, in fact, is a secondary trap of the thermostatic type.

Ball float and thermostatic steam traps LFT 442
Other Ball float thermostatic steam traps:
Ball float & thermostatic LFT 14 Ball float & thermostatic LFT 441 Ball float & thermostatic LFT 443 Ball float & thermostatic BF G600 Ball float and thermostatic steam traps LFT 442

CDB ENGINEERING SPA
 

Tel. +39 0377 912268/5

Fax +39 0377 910668

Email info@cdbengineering.com

Limiting Conditions
RatingANSI 300
PMA50 bar
TMA410°C
Max Differential Pressure (Barg)4,5 - 10 - 14 - 21 - 32
Sizes
1.1/2" - 2"
Connections
ScrewedASME B1.20.1 (NPT) BS21 (BSP)
Socket weldASME B16.11
FlangedASME B16.5/UNI/DIN

Main Features:

Excellent air venting by thermostatic air vent

Discharge condensate at steam temperature

Operates with saturated and superheated steam

Suitable for heavy condensate load

Simple and reliable construction

Ordering Information:

Inlet pressure

Back pressure

Operating temperature

Condensate load

End connections

FLOW RATE CAPACITY (Kg/h)
DNDP MAX Bar (PSI)Differential Pressure
0,340,691,382,763,454,55,526,98,621012,4142127,632
404,5 (65)190727243996567561296810         
10 (145)1272177125433632408645405221590264476810     
14 (200)81811811635227024752724313335423905408643824540   
21 (300)818118116352270247527243133354239054086438245405902  
32 (464)81811811635227024752724313335423905408643824540590264936810
504,5 (65)6129899012712181602043022927         
10 (145)3315454065839080102151180413166145281589018160     
14 (200)158922703088435947675448612968107491794586269080   
21 (300)15892270308843594767544861296810749179458626908012258  
32 (464)158922703088435947675448612968107491794586269080122581353014074
PosDescriptionMaterialsMaterialsSpares
1BodyASTM A216 WCBASTM A351 CF8M 
2CoverASTM A216 WCBASTM A351 CF8M 
3GasketSW 316/GraphiteSW 316/GraphiteX
4,5,6Valve AssemblySS 316LSS 316LX
7Ball floatSS 316LSS 316LX
8Thermostatic air ventSSSSX
9BoltingB7/2HB8/Gr8 
Ball float and thermostatic steam traps LFT 442
Size (inches)ABC   S (flgd)          SF (sw or scrw.)Weight (Kg)
1.1/2"25013011032040
2"25013013032040
Dimensions: A, B, C, S are in millimeters (mm)

11/02

Installation:

The trap should be installed with the float arm in horizontal plane. Must be fitted below the drain point of the equipment.

Isolating valve should be installed upstream and downstream of the trap for safe maintenance.

Always open isolation valve slowly until normal operating conditions are achieved to avoid system shocks.

Maintenance:

The trap can be maintained without disturbing the piping connections. Ensure that trap is isolated upstream and downstream before attempting to dismantle it. Allow the trap to cool before dismantling.

Item 3 (gasket), 4-5-6 (valve assembly), 7 (ball float) and 8 (air vent) can be replaced bring the traps as new conditions.