Limiting Conditions
RatingANSI 300
PMA50 bar
TMA400°C
Max Differential Pressure (Barg)28

CDB ENGINEERING SPA
 

Tel. +39 0377 912268/5

Fax +39 0377 910668

Email info@cdbengineering.com

Sizes
1/2" - 3/4" - 1"
Connections
ScrewedASME B1.20.1 (NPT) BS21 (BSP)
Socket weldASME B16.11
FlangedASME B16.5 - UNI - DIN
Inverted bucket steam traps D701
PosDescriptionMaterials
1BodySS 304
2CoverSS 304
3, 4, 5MechanismSS 304
6PipeSS 304
7BucketSS 304
 FlangesA105/F304
Inverted bucket steam traps D701
Size (inches)ABCD

L

Weight (Kg)
1/2"9619165641502
3/4"9619165641502,5
1"9619165641603
Dimensions: A, B, C, D, L are in millimeters (mm)