ITALIANO
CDB ENGINEERING SPA

Your Partner in filtration and process equipment

Filters and Strainers » Strainers » Forged "Y" Type "FYF" 800#

Other Strainers:

Forged Cast Fabricated Fabricated Pressure Angle Conical strainers Flat strainers

Designed to asme b16.34 the strainer bodies are produced with a superior wall thickness for corrosion allowance.

Standard strainers are equipped with screens for the average service of most mediums ( steam, gas, air, oil, chemicals , ect. ).

The large screen open area ensures an efficient filtering action with a low pressure drop.

Filtering area to inlet area ratio is larger than 3 to 1 .

Screens area manufactured with perforated plate in the materials and with the perforation specified in the relevant tables .

Different filtrations or materials are available on request.

POS.DESCR.STD MAT.STD MAT.SPARE
1BODYASTM A 105NASTM A 182 F316 
2COVERASTM A 105NASTM A 182 F316 
3SCREENSs 304Ss 316X
4STUD BOLTSASTM A 193 B7ASTM A 193 B8 
5NUTSASTM A 194 2HASTM A 194 GR8 
6GASKETSw 316/GRAPHITESw 316/GRAPHITEX
7DRAIN PLUGASTM A 105NASTM A 182 F316 
8FLANGESASTM A 105NASTM A 182 F316 

CDB ENGINEERING SPA
 

Tel. +39 0377 912268/5

Fax +39 0377 910668

Email info@cdbengineering.com

CONNECTIONS
SCREWEDANSI B1.20.1 (NPT)/BS21 /BSP)
BUTTWELDANSI B16.25
SOCKET WELDINGANSI B16.11
FLANGEDANSI/UNI/DIN
SIZE
(INCHES)
DRAIN PLUGLHH1WEIGHT (KG)

UNI-DIN
PN 16-25-40

RF-150#RF-300#RF-600#
LKGLKGLKGLKG
3/8"1/4"9060851--------
1/2"1/2"989911311532.61782.31872.82003.2
3/4"1/2"9899113115341823.21904.32054.7
1"1/2"11111013031664.42024.22145.32275.8
1 1/2"1/2"1401381626203112439.72561327115
2"1/2"1701682001123313270122831530216.3

STANDARD PERFORATIONS 0,8MM

SPECIAL PERFORATIONS ON REQUEST

DIMENSIONS: L, H, H1 ARE IN MILLIMETERS (MM)

03/10
Strainers Forged Strainers Forged Strainers Forged

» All strainers should be installed as closed as possible to the machinery which they are being installed to protect. It is important to ensure that the strainers installed with the flow following the same direction as the flow direction arrow cast onto the strainer body.

» For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

» "Y" - strainers should never be installed in vertical pipelines in the upward flow condition. 

CDB ENGINEERING RESERVE THE RIGHT TO CARRY OUT ANY NECESSARY MODIFICATION WITHOUT PRIOR NOTICE

COMPANY

PRODUCTS

INFO

Linkedin Youtube chanel

All right reserved. Copyright 2017 by CDB ENGINEERING SPA

Address: L. Maggi, 19 - 26841 Casalpusterlengo (LO) Italy

Paid up share Capital Euro 1.050.000,00 i.v.

VAT NO. 02977730965 - N. REA 1449742

Trademarks are register by their owner